{"id":26393,"date":"2026-09-30T01:38:10","date_gmt":"2026-09-30T01:38:10","guid":{"rendered":"https:\/\/trumonytechs.com\/?p=26393"},"modified":"2026-09-30T01:38:10","modified_gmt":"2026-09-30T01:38:10","slug":"systemlosningar-for-lagring-av-batterienergi","status":"publish","type":"post","link":"https:\/\/www.trumonytechs.com\/sv\/battery-energy-storage-system-solutions\/","title":{"rendered":"Hur man v\u00e4ljer en konfiguration f\u00f6r batterilagringssystem"},"content":{"rendered":"<p class=\"wp-block-paragraph\">A battery energy storage system solution is an integrated package \u2014 cells, battery management system, power conversion system, energy management software, thermal management, and fire safety hardware \u2014 sized against a specific duty cycle, not a capacity number. The configuration that fits depends on three things you can determine before contacting any supplier: your power-to-energy ratio, your site&#8217;s ambient and space constraints, and the discharge frequency your application demands. Chemistry follows from these, not the other way around. Two projects with identical megawatt-hour ratings can require different cooling architectures and different fire-protection budgets.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Vad en BESS-l\u00f6sning inkluderar ut\u00f6ver batterierna<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Six interdependent subsystems make up a <a href=\"https:\/\/www.trumonytechs.com\/sv\/what-is-a-battery-energy-storage-system\/\">batterienergilagringssystem<\/a> solution; on high-power or space-constrained projects, the thermal limit usually binds before the others. Battery modules store the charge. The battery management system tracks cell voltage, temperature, and state of charge. The power conversion system moves energy between DC storage and AC grid or load in both directions. The energy management system decides when charging and discharging happen, working against price signals, load profile, and grid conditions. Thermal management holds cells inside their operating window. Safety systems detect, contain, and suppress failure events. A full delivery scope typically adds DC protection, AC switchgear, transformer, metering, SCADA and communications, auxiliary power, gas detection, ventilation, grounding, and cybersecurity controls.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Vilken begr\u00e4nsning som binder f\u00f6rst \u00e4r projektspecifik. I andra projekt kan sammankopplingskapacitet, transformator- eller PCS-klassificeringar, platslayout och brandseparation, bullergr\u00e4nser eller tillst\u00e5nd dominera innan n\u00e5gon termisk gr\u00e4ns uppn\u00e5s. Det som generellt g\u00e4ller \u00e4r kopplingen. PCS-klassificeringen s\u00e4tter en \u00f6vre gr\u00e4ns f\u00f6r hur snabbt paketet kan cykla. Realiserad cyklingshastighet \u2013 som ocks\u00e5 formas av anv\u00e4ndbar energi, liksp\u00e4nningsf\u00f6nster, BMS-str\u00f6mgr\u00e4nser samt SOC- och temperaturnedklassning \u2013 driver v\u00e4rmegenerering. V\u00e4rmegenerering begr\u00e4nsar kylarkitekturen, och kylarkitekturen s\u00e4tter kapslingens fotavtryck och parasitbelastning.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Kraft och energi \u00e4r tv\u00e5 separata specifikationer<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Sizing a battery energy storage system takes two independent numbers: power in megawatts and energy in megawatt-hours. Confuse them, and you get a system correctly sized for the wrong problem. Power describes how much the system delivers at any instant. Energy describes how long it sustains that delivery. A 1 MW \/ 4 MWh system delivers its full rated output for roughly four hours; a 1 MW \/ 1 MWh system delivers the same instantaneous power for about one hour.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">B\u00e5da siffrorna beh\u00f6ver randvillkor innan de betyder n\u00e5got i ett kontrakt. Ange om energin \u00e4r levererad med likstr\u00f6m eller v\u00e4xelstr\u00f6m, om den \u00e4r nominell eller anv\u00e4ndbar efter SOC-reserv, om den anges vid b\u00f6rjan av livscykeln eller garanteras vid slutet av livscykeln, och om tur- och retureffektiviteten inkluderar PCS och hj\u00e4lplaster. Tv\u00e5 offerter med samma MWh-siffra kan skilja sig v\u00e4sentligt \u00e5t i levererad energi n\u00e4r dessa gr\u00e4nser till\u00e4mpas.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The ratio between power and energy \u2014 the C-rate \u2014 is a useful first-pass indicator of thermal demand, though it cannot replace cell-level resistance data and a time-resolved duty-cycle model. For systems of the same nominal energy capacity and DC voltage, cutting discharge duration from four hours to one raises current by roughly four times. Under a simplified constant-resistance model, instantaneous I\u00b2R heat-generation power rises by approximately sixteen times. Cumulative resistive heat over the full discharge rises by approximately four times, since the discharge lasts a quarter as long. Actual values depend on cell resistance, state of charge, temperature, and voltage architecture.<\/p>\n\n\n\n<figure class=\"wp-block-image\"><img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"450\" src=\"https:\/\/www.trumonytechs.com\/wp-content\/uploads\/2026\/09\/bess-discharge-duration-cooling-load.webp\" alt=\"Diagram linking shorter discharge duration to higher peak heat generation in a battery energy storage system configuration\" class=\"wp-image-37955\" srcset=\"https:\/\/www.trumonytechs.com\/wp-content\/uploads\/2026\/09\/bess-discharge-duration-cooling-load.webp 800w, https:\/\/www.trumonytechs.com\/wp-content\/uploads\/2026\/09\/bess-discharge-duration-cooling-load-300x169.webp 300w, https:\/\/www.trumonytechs.com\/wp-content\/uploads\/2026\/09\/bess-discharge-duration-cooling-load-768x432.webp 768w, https:\/\/www.trumonytechs.com\/wp-content\/uploads\/2026\/09\/bess-discharge-duration-cooling-load-18x10.webp 18w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">The gap between peak power and cumulative energy is what turns duration into a cooling question, not a capacity one. A cooling system has to reject the instantaneous peak; the average understates what it faces. Two systems storing identical energy, one cycling in an hour and one over four, therefore present cooling loads that differ by far more than their nameplate ratings suggest. This is why frequency-regulation assets and four-hour arbitrage assets rarely share a cooling architecture even when their capacities match, and why a high-C-rate application narrows the viable set of chemistries and enclosures before any commercial preference is applied.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">D\u00e4r kemi begr\u00e4nsar beslutet<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Battery chemistry sets the thermal and safety envelope a solution is designed around. Its practical effect on configuration, though, is narrower than most comparison tables suggest. Lithium iron phosphate is generally more thermally stable than <a href=\"https:\/\/www.trumonytechs.com\/sv\/ev-vs-ess-battery\/\">nickel-mangan-kobolt<\/a> formuleringar, vilket p\u00e5verkar prestandan vid brandtester p\u00e5 systemniv\u00e5. Blysyra f\u00f6rblir anv\u00e4ndbart d\u00e4r kostnaden dominerar och cykleantalet \u00e4r l\u00e5gt. Fl\u00f6desbatterier frikopplar effekt fr\u00e5n energi genom att skala upp stapel och tankar oberoende av varandra, vid l\u00e4gre energit\u00e4thet. Natriumbaserade kemier \u00e4r en framv\u00e4xande klass som \u00e4r positionerad p\u00e5 material\u00f6verfl\u00f6d.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Most guides present chemistry as the first decision, yet its dominant downstream consequence is thermal and regulatory, not electrical. A chemistry with greater intrinsic thermal stability may improve system-level fire-test performance. Separation distances and suppression requirements, however, are determined by the listed system configuration, the applicable code edition, UL 9540A test data, installation layout, and AHJ acceptance \u2014 not by chemistry alone. A chemistry selected without its thermal and code consequences priced in is a decision made twice.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Termisk hantering \u00e4r d\u00e4r BESS-konfigurationer skiljer sig \u00e5t<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Thermal architecture is a system-level routing decision. It is also the specification most likely to be inherited unexamined from a reference design built for a different C-rate. Commercial BESS products primarily use HVAC-based <a href=\"https:\/\/www.trumonytechs.com\/sv\/typer-av-batterikylsystem\/\">luftkylning<\/a> eller indirekt v\u00e4tskekylning. Immersionskylning \u00e4r ett framv\u00e4xande alternativ d\u00e4r temperaturuniformitet eller utbredningsmotst\u00e5nd \u00e4r prioriterat, \u00e4ven om dess implementeringsbas och tj\u00e4nsteekosystem fortfarande \u00e4r mer begr\u00e4nsade.<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table>\n<tr><th>Kylningsv\u00e4g<\/th><th>L\u00e4mplig f\u00f6r<\/th><th>Huvudbegr\u00e4nsning<\/th><\/tr>\n<tr><td>Varmluft (HVAC)<\/td><td>L\u00e5g koldioxidhalt, m\u00e5ttlig omgivningstemperatur, kostnadsk\u00e4nsliga platser<\/td><td>Luftens l\u00e5ga v\u00e4rmekapacitet begr\u00e4nsar borttagningshastigheten; gradienter v\u00e4xer \u00f6ver stora f\u00f6rpackningar<\/td><\/tr>\n<tr><td>Indirekt v\u00e4tska (kall platta)<\/td><td>M\u00e5ttlig till h\u00f6g C-halt, t\u00e4t packning, breda omgivningssv\u00e4ngningar<\/td><td>Kr\u00e4ver kylv\u00e4tskeslinga, pumpparasiter och l\u00e4ckageteknik<\/td><\/tr>\n<tr><td>Neds\u00e4nkning<\/td><td>H\u00f6g C-hastighet, h\u00f6gt krav p\u00e5 likformighet, prioritet f\u00f6r utbredningsmotst\u00e5nd<\/td><td>V\u00e4tskekompatibilitet, vikt, servicev\u00e4nlighet, begr\u00e4nsad drifts\u00e4ttningsbas<\/td><\/tr>\n<\/table>\n<\/figure>\n\n\n\n<figure class=\"wp-block-image\"><img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"450\" src=\"https:\/\/www.trumonytechs.com\/wp-content\/uploads\/2026\/09\/bess-cooling-route-selection.webp\" alt=\"Decision diagram routing duty cycle and site constraints to air, liquid, or immersion cooling for a BESS configuration\" class=\"wp-image-37956\" srcset=\"https:\/\/www.trumonytechs.com\/wp-content\/uploads\/2026\/09\/bess-cooling-route-selection.webp 800w, https:\/\/www.trumonytechs.com\/wp-content\/uploads\/2026\/09\/bess-cooling-route-selection-300x169.webp 300w, https:\/\/www.trumonytechs.com\/wp-content\/uploads\/2026\/09\/bess-cooling-route-selection-768x432.webp 768w, https:\/\/www.trumonytechs.com\/wp-content\/uploads\/2026\/09\/bess-cooling-route-selection-18x10.webp 18w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">In a configuration decision, specify temperature spread at a stated level \u2014 cell, module, or rack \u2014 not just an average, because average-temperature figures cannot tell these three routes apart. Temperature non-uniformity across modules creates differences in internal resistance, available power, and ageing rate. Over time those differences increase cell imbalance, and the BMS reaches its voltage or temperature limits on the outlying modules before the pack as a whole is exhausted, which reduces usable system energy. A route that lowers average temperature while widening spread can cost more usable energy than it saves in cooling load.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Route selection is where this article stops; the mechanism behind that spread is pack-level engineering. That heat path moves in stages \u2014 from cell and module, across the thermal interface materials that couple them to the cold plate, into the liquid-cooling loop that carries heat away. Trumonytechs supplies the interface materials and cold-plate liquid-cooling components that sit at those middle stages. Matching a specific material or plate to a gap, an assembly stress, or a flow target is a separate engineering step, and the model-level conductivity or insulation values belong with verified product data, not a routing decision. The heat-generation sources, optimal lithium-ion operating windows, and cold plate heat-transfer design behind the spread fall under <a href=\"https:\/\/www.trumonytechs.com\/sv\/optimering-av-termisk-hantering-av-batteripaket\/\">optimering av termisk hantering av batteripaket<\/a>, a pack-level layer beneath this routing decision. Where the route is already fixed and the question is hardware and simulation scope, that sits with <a href=\"https:\/\/www.trumonytechs.com\/sv\/termisk-hantering-av-batteripaket\/\">termisk hantering av batteripaket<\/a>.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Standarder som definierar s\u00e4kerhetsbaslinjen<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">United States BESS compliance spans product standards, fire and building codes, electrical installation requirements, and project-specific AHJ conditions. No single document covers it. UL 9540 is the safety standard for energy storage systems and equipment; systems are listed to it, not certified by it. UL 9540A is a test method for evaluating <a href=\"https:\/\/www.trumonytechs.com\/sv\/termisk-rusning\/\">termisk rusning<\/a> fire propagation. It produces empirical data, not a pass\/fail result \u2014 data that designers and authorities having jurisdiction use to set separation distances, venting, and fire control strategies. Per UL Solutions, that evaluation runs at cell, module, unit, and installation levels. NFPA 855 is the installation standard for stationary energy storage systems, addressing barriers, suppression, monitoring, and ventilation at the site level. It carries force where a state, city, or AHJ has adopted or referenced it.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">UL 9540, UL 9540A, and NFPA 855 sit alongside the adopted IFC or NFPA 1, NEC Article 706 for electrical installation, UL 1973 for batteries in stationary applications, UL 1741 for PCS and interconnection equipment, and local interconnection requirements. Projects outside the United States work to equivalent frameworks, with the IEC 62619 and IEC 62933 series as the usual reference points. Confirm the applicable set for the destination market before configuration is fixed.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Eftersom UL 9540A-resultaten p\u00e5verkar hur str\u00e4nga NFPA 855-kraven blir, p\u00e5verkar ett systems testdata kostnaden p\u00e5 platsniv\u00e5 innan en grund gjuts. Att beg\u00e4ra dessa data \u00e4r en indata f\u00f6r platskostnaden, inte en efterlevnadsformalitet. Rapporten \u00e4r endast till hj\u00e4lp om den testade konfigurationen matchar den f\u00f6reslagna installationen. Bekr\u00e4fta vilka utg\u00e5vor som g\u00e4ller i m\u00e5ljurisdiktionen, eftersom kraven skiljer sig \u00e5t beroende p\u00e5 kapacitet, separationsavst\u00e5nd och bostads- kontra icke-bostadsinstallation.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Vilken variabel som ska bekr\u00e4ftas f\u00f6rst<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Settle two inputs before any other specification work begins: the duty cycle (discharge duration, cycles per day, depth of discharge) and the site&#8217;s thermal and spatial envelope (ambient range, available footprint, indoor or outdoor placement).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Both are expensive or impossible to change later. Duty cycle is set by the commercial application, and the site is usually a fixed asset. Other variables retain some flexibility during concept design, but chemistry, enclosure architecture, and supplier platform should be frozen before detailed permitting, fire analysis, and balance-of-plant design. Each of those activities consumes the earlier choices as fixed inputs. Fixing a flexible variable before a fixed one produces the most common failure mode in BESS procurement: a system correctly built to a specification that no longer matches the application.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">F\u00f6r kortvariga backup-applikationer utan tidsf\u00f6rdelning och utan exponering f\u00f6r efterfr\u00e5gan\/belastning kan en generator eller UPS mycket v\u00e4l ha den l\u00e4gre installerade <a href=\"https:\/\/www.trumonytechs.com\/sv\/ess-battery-cost\/\">kostnad per levererad kilowattimme<\/a>. Battery storage is worth questioning there. The honest comparison needs a lifecycle model covering outage frequency and duration, fuel and maintenance, emissions and noise constraints, response time, demand-charge savings, any grid-service or capacity revenue, and the cost of unserved load. Storage generally earns its cost where it performs several functions at once. A single-function case can still stand up, but it should be tested, not assumed.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Parametrar v\u00e4rda att bekr\u00e4fta skriftligen innan offerter j\u00e4mf\u00f6rs:<\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table>\n<tr><th>Parameter<\/th><th>Vad som ska bekr\u00e4ftas<\/th><\/tr>\n<tr><td>Nominell v\u00e4xelstr\u00f6m<\/td><td>Kontinuerlig och \u00f6verbelastningsklassificering<\/td><\/tr>\n<tr><td>Anv\u00e4ndbar AC-energi<\/td><td>Vid BOL och garanterad vid EOL<\/td><\/tr>\n<tr><td>Varaktighet<\/td><td>Vid nominell AC-utg\u00e5ng<\/td><\/tr>\n<tr><td>Effektivitet tur och retur<\/td><td>Testa gr\u00e4ns- och hj\u00e4lplaster<\/td><\/tr>\n<tr><td>Tillg\u00e4nglighet<\/td><td>Definition och undantag<\/td><\/tr>\n<tr><td>Temperaturj\u00e4mnhet<\/td><td>M\u00e4tniv\u00e5: cell, modul eller rack<\/td><\/tr>\n<tr><td>Hj\u00e4lpf\u00f6rbrukning<\/td><td>Standby- och fulllastf\u00f6rh\u00e5llanden<\/td><\/tr>\n<tr><td>Degradering<\/td><td>Kalender- och cykelantaganden<\/td><\/tr>\n<tr><td>Brandprovning<\/td><td>Exakt testad konfiguration<\/td><\/tr>\n<tr><td>Garanti<\/td><td>Genomstr\u00f6mning, cykler, SOC och temperaturgr\u00e4nser<\/td><\/tr>\n<\/table>\n<\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Var du ska b\u00f6rja med din BESS-specifikation<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Tv\u00e5 variabler avg\u00f6r: den driftcykel som applikationen st\u00e4ller och det termiska och rumsliga h\u00f6ljet som platsen erbjuder. Om du korrigerar dessa, f\u00f6ljer kemi, kylv\u00e4g och h\u00f6lje med mindre gissningsarbete. Allt nedstr\u00f6ms \u2013 nedbrytningsprognoser, brandskyddsbudget, fotavtryck \u2013 \u00e4rver fr\u00e5n dem.<\/p>\n\n\n\n<figure class=\"wp-block-image\"><img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"600\" src=\"https:\/\/www.trumonytechs.com\/wp-content\/uploads\/2026\/09\/bess-cold-plate-liquid-cooling-detail.webp\" alt=\"Liquid cold plate and coolant manifold on the cell-to-coolant path of a battery energy storage system configuration\" class=\"wp-image-37954\" srcset=\"https:\/\/www.trumonytechs.com\/wp-content\/uploads\/2026\/09\/bess-cold-plate-liquid-cooling-detail.webp 800w, https:\/\/www.trumonytechs.com\/wp-content\/uploads\/2026\/09\/bess-cold-plate-liquid-cooling-detail-300x225.webp 300w, https:\/\/www.trumonytechs.com\/wp-content\/uploads\/2026\/09\/bess-cold-plate-liquid-cooling-detail-768x576.webp 768w, https:\/\/www.trumonytechs.com\/wp-content\/uploads\/2026\/09\/bess-cold-plate-liquid-cooling-detail-16x12.webp 16w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">What remains project-specific is the interaction between duty cycle and local code environment, which no article resolves remotely. Where a pack&#8217;s cooling assumption is carried over from a lower-C-rate reference design without verification, the usual result is acceptable average temperatures alongside unacceptable module-to-module spread. The correction at that stage is a redesign, not a tuning exercise. Trumonytechs&#8217; cold-plate and liquid-cooling components do their work at exactly this point, weighing the routes against a stated duty cycle, not a nominal rating, because they diverge most at the operating points where nominal figures converge.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Innan n\u00e4sta leverant\u00f6rssamtal, sammanst\u00e4ll urladdningstiden och cykler per dag-profilen, topp- och genomsnittlig effektf\u00f6rbrukning, platsens \u00e5rliga omgivningstemperaturintervall, tillg\u00e4ngligt utrymmesutrymme och placering inomhus eller utomhus, gr\u00e4nsen f\u00f6r n\u00e4tanslutning och AHJ:s nuvarande position g\u00e4llande brandprovning p\u00e5 installationsniv\u00e5. Med dessa sex indata kan en leverant\u00f6r dimensionera ett system och priss\u00e4tta dess termiska och s\u00e4kerhetsm\u00e4ssiga omfattning utan antaganden som ers\u00e4tter data.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Var den h\u00e4r artikeln slutar<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Tre beslut ligger precis utanf\u00f6r den h\u00e4r artikelns omfattning, vart och ett med en s\u00e4rskild v\u00e4gledning:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Cooling loop and cold plate design \u2014 once the route is fixed, channel geometry, flow balancing, and pump sizing follow. See <a href=\"https:\/\/www.trumonytechs.com\/sv\/liquid-cooling-system-design\/\">Design av v\u00e4tskekylsystem f\u00f6r elbilsbatterier och termisk hantering av ESS<\/a>.<\/li>\n<li>Thermal runaway prevention at system level \u2014 the standards section here gives compliance coordinates only; the engineering behind propagation resistance is covered in <a href=\"https:\/\/www.trumonytechs.com\/sv\/prevent-thermal-runaway-in-bess\/\">hur man f\u00f6rhindrar termisk rusning i BESS<\/a>.<\/li>\n<li>Installed cost ranges \u2014 this article deliberately avoids price figures, since they move with chemistry, market, and scale. Current ranges are in <a href=\"https:\/\/www.trumonytechs.com\/sv\/solar-battery-storage-system-cost\/\">kostnad f\u00f6r solcellsbatterilagringssystem<\/a>.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">VANLIGA FR\u00c5GOR<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Betyder en h\u00f6gre MWh-klassning ett system som h\u00e5ller l\u00e4ngre?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Nej. Kapacitet avg\u00f6r varaktighet, inte livsl\u00e4ngd. <a href=\"https:\/\/www.trumonytechs.com\/sv\/energy-storage-system-lifespan\/\">Livscykel<\/a> beror p\u00e5 urladdningsdjup, driftstemperatur och koldioxidhalt \u2014 ett stort system som cyklas h\u00e5rt i ett varmt klimat kan brytas ner snabbare \u00e4n ett mindre som drivs f\u00f6rsiktigt.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Vad \u00e4r skillnaden mellan AC-m\u00e4rkt och DC-m\u00e4rkt kapacitet?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Likstr\u00f6mskapaciteten m\u00e4ts vid batteriets poler. V\u00e4xelstr\u00f6mskapaciteten \u00e4r den som n\u00e5r anslutningspunkten efter PCS-omvandling och hj\u00e4lpbelastningar. Levererbar v\u00e4xelstr\u00f6msenergi \u00e4r alltid l\u00e4gre, och gapet vidgas n\u00e4r hj\u00e4lpf\u00f6rbrukningen \u00f6kar, vilket \u00e4r anledningen till att kylarkitekturen p\u00e5verkar det antal som en garanti kan skrivas mot.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Kan kylarkitekturen \u00e4ndras efter installationen?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">S\u00e4llan utan betydande omarbetning, eftersom rutten avg\u00f6r kapslingens geometri, strukturell belastning och ofta sj\u00e4lva paketets design.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Kr\u00e4ver alla BESS-installationer UL 9540A-testning?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Requirements vary by capacity, separation distance, and installation type, and the applicable edition depends on jurisdiction. Confirm with the AHJ instead of assuming a blanket rule.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Vad b\u00f6r en BESS-f\u00f6rfr\u00e5gan inneh\u00e5lla?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Duty cycle, site ambient range, footprint and placement, interconnection limit, and the AHJ&#8217;s position on fire testing. Without these, a supplier substitutes assumptions for data, and the quotation reflects the assumptions instead of the site.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Vidare l\u00e4sning<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/www.ul.com\/services\/ul-9540a-test-method\">UL 9540A Test Method for Battery Energy Storage Systems (BESS)<\/a> \u2014 UL Solutions (standards body). Defines the cell\/module\/unit\/installation fire-propagation test; the data is used by designers and AHJs to determine separation and fire-control measures, which supports this article&#8217;s point that requesting UL 9540A results is a site-cost input, not a formality.<\/li>\n<li><a href=\"https:\/\/www.ul.com\/resources\/installation-codes-and-requirements-energy-storage-systems-ess-faqs\">Installation Codes and Requirements for Energy Storage Systems (ESS) \u2013 FAQs<\/a> \u2014 UL Solutions. Clarifies which codes and test-level requirements apply by residential versus non-residential installation and edition, supporting the standards-baseline section.<\/li>\n<li><a href=\"https:\/\/www.nfpa.org\/product\/nfpa-855-standard\/p0855code\">NFPA 855, Standard for the Installation of Stationary Energy Storage Systems<\/a> \u2014 NFPA (standards body). The site-level installation standard referenced for barriers, suppression, monitoring, and ventilation; confirm the edition adopted in your jurisdiction with the AHJ.<\/li>\n<\/ul>\n\n\n<!-- related-posts:start -->\n\n\n<h2 class=\"wp-block-heading\">Relaterade artiklar<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/www.trumonytechs.com\/sv\/what-is-an-energy-cell\/\">Vad \u00e4r en energicell? Batteriteknikens definition, design och termisk hantering<\/a> \u2014 Defines the cell as the building block behind the MW\/MWh and thermal limits discussed here, at the unit level.<\/li>\n<li><a href=\"https:\/\/www.trumonytechs.com\/sv\/what-is-a-potting-compound\/\">Vad \u00e4r en ingjutningsmassa: Anv\u00e4ndningsomr\u00e5den och f\u00f6rdelar<\/a> \u2014 Explains how potting compounds protect and thermally couple battery-pack electronics that sit alongside the cooling path.<\/li>\n<li><a href=\"https:\/\/www.trumonytechs.com\/sv\/the-difference-between-potting-and-sealing\/\">Vad \u00e4r skillnaden mellan ingjutning och f\u00f6rsegling?<\/a> \u2014 Separates two protection methods a pack engineer chooses between when enclosing modules and electronics.<\/li>\n<li><a href=\"https:\/\/www.trumonytechs.com\/sv\/vilka-ar-de-basta-materialen-for-att-forsegla-ev-batterier\/\">Vilka \u00e4r de b\u00e4sta materialen f\u00f6r att f\u00f6rsegla EV-batterier?<\/a> \u2014 Reviews sealing and interface material options for battery packs, extending the interface-material step in the heat path.<\/li>\n<li><a href=\"https:\/\/www.trumonytechs.com\/sv\/thermal-paste-alternative\/\">Alternativ till termisk pasta: Konstruerade alternativ och hur man v\u00e4ljer<\/a> \u2014 Compares engineered thermal interface options that couple cells to the cold plate in the cell-to-coolant route.<\/li>\n<\/ul>\n\n\n<!-- related-posts:end -->","protected":false},"excerpt":{"rendered":"<p>A battery energy storage system solution is an integrated package \u2014 cells, battery management system, power conversion system, energy management software, thermal management, and fire safety hardware \u2014 sized against a specific duty cycle, not a capacity number. The configuration that fits depends on three things you can determine before contacting any supplier: your power-to-energy &#8230; <a title=\"Hur man v\u00e4ljer en konfiguration f\u00f6r batterilagringssystem\" class=\"read-more\" href=\"https:\/\/www.trumonytechs.com\/sv\/battery-energy-storage-system-solutions\/\" aria-label=\"L\u00e4s mer om How to Choose a Battery Energy Storage System Configuration\">L\u00e4s mer<\/a><\/p>","protected":false},"author":2,"featured_media":37953,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[174],"tags":[78,76,176,81,169],"class_list":["post-26393","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-trumonytechs-news","tag-battery-cooling","tag-battery-pack-cooling","tag-battery-thermal-management","tag-ev-battery-cooling","tag-liquid-cold-plate"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.6 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>How to Choose a Battery Energy Storage System Configuration<\/title>\n<meta name=\"description\" content=\"How to choose a battery energy storage system configuration: weigh duty cycle, C-rate, cooling route, and UL 9540A before comparing supplier quotes.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.trumonytechs.com\/sv\/systemlosningar-for-lagring-av-batterienergi\/\" \/>\n<meta property=\"og:locale\" content=\"sv_SE\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"How to Choose a Battery Energy Storage System Configuration\" \/>\n<meta property=\"og:description\" content=\"How to choose a battery energy storage system configuration: weigh duty cycle, C-rate, cooling route, and UL 9540A before comparing supplier quotes.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.trumonytechs.com\/sv\/systemlosningar-for-lagring-av-batterienergi\/\" \/>\n<meta property=\"og:site_name\" content=\"Trumonytechs\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/trumonytechs\/\" \/>\n<meta property=\"article:published_time\" content=\"2026-09-30T01:38:10+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.trumonytechs.com\/wp-content\/uploads\/2026\/09\/bess-configuration-utility-scale-hero.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"800\" \/>\n\t<meta property=\"og:image:height\" content=\"600\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"author\" content=\"Trumonytechs\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@Trumonytechs\" \/>\n<meta name=\"twitter:site\" content=\"@Trumonytechs\" \/>\n<meta name=\"twitter:label1\" content=\"Skriven av\" \/>\n\t<meta name=\"twitter:data1\" content=\"Trumonytechs\" \/>\n\t<meta name=\"twitter:label2\" content=\"Ber\u00e4knad l\u00e4stid\" \/>\n\t<meta name=\"twitter:data2\" content=\"7 minuter\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.trumonytechs.com\\\/battery-energy-storage-system-solutions\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.trumonytechs.com\\\/battery-energy-storage-system-solutions\\\/\"},\"author\":{\"name\":\"Trumonytechs\",\"@id\":\"https:\\\/\\\/www.trumonytechs.com\\\/#\\\/schema\\\/person\\\/eb4f36f93231f994effde9f9223a8c7b\"},\"headline\":\"How to Choose a Battery Energy Storage System Configuration\",\"datePublished\":\"2026-09-30T01:38:10+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.trumonytechs.com\\\/battery-energy-storage-system-solutions\\\/\"},\"wordCount\":2539,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/www.trumonytechs.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/www.trumonytechs.com\\\/battery-energy-storage-system-solutions\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.trumonytechs.com\\\/wp-content\\\/uploads\\\/2026\\\/09\\\/bess-configuration-utility-scale-hero.webp\",\"keywords\":[\"Battery Cooling\",\"Battery Pack Cooling\",\"Battery Thermal Management\",\"Ev Battery Cooling\",\"Liquid cold plate\"],\"articleSection\":[\"Trumonytechs News\"],\"inLanguage\":\"sv-SE\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.trumonytechs.com\\\/battery-energy-storage-system-solutions\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.trumonytechs.com\\\/battery-energy-storage-system-solutions\\\/\",\"url\":\"https:\\\/\\\/www.trumonytechs.com\\\/battery-energy-storage-system-solutions\\\/\",\"name\":\"How to Choose a Battery Energy Storage System Configuration\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.trumonytechs.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.trumonytechs.com\\\/battery-energy-storage-system-solutions\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.trumonytechs.com\\\/battery-energy-storage-system-solutions\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.trumonytechs.com\\\/wp-content\\\/uploads\\\/2026\\\/09\\\/bess-configuration-utility-scale-hero.webp\",\"datePublished\":\"2026-09-30T01:38:10+00:00\",\"description\":\"How to choose a battery energy storage system configuration: weigh duty cycle, C-rate, cooling route, and UL 9540A before comparing supplier quotes.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.trumonytechs.com\\\/battery-energy-storage-system-solutions\\\/#breadcrumb\"},\"inLanguage\":\"sv-SE\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.trumonytechs.com\\\/battery-energy-storage-system-solutions\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"sv-SE\",\"@id\":\"https:\\\/\\\/www.trumonytechs.com\\\/battery-energy-storage-system-solutions\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.trumonytechs.com\\\/wp-content\\\/uploads\\\/2026\\\/09\\\/bess-configuration-utility-scale-hero.webp\",\"contentUrl\":\"https:\\\/\\\/www.trumonytechs.com\\\/wp-content\\\/uploads\\\/2026\\\/09\\\/bess-configuration-utility-scale-hero.webp\",\"width\":800,\"height\":600,\"caption\":\"Outdoor utility-scale battery energy storage system enclosures sized to a duty cycle and site footprint\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.trumonytechs.com\\\/battery-energy-storage-system-solutions\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.trumonytechs.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"How to Choose a Battery Energy Storage System Configuration\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.trumonytechs.com\\\/#website\",\"url\":\"https:\\\/\\\/www.trumonytechs.com\\\/\",\"name\":\"Trumonytechs\",\"description\":\"Thermal Management System Solutions\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.trumonytechs.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.trumonytechs.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"sv-SE\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.trumonytechs.com\\\/#organization\",\"name\":\"Trumonytechs\",\"url\":\"https:\\\/\\\/www.trumonytechs.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"sv-SE\",\"@id\":\"https:\\\/\\\/www.trumonytechs.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.trumonytechs.com\\\/wp-content\\\/uploads\\\/2022\\\/06\\\/10001-1.png\",\"contentUrl\":\"https:\\\/\\\/www.trumonytechs.com\\\/wp-content\\\/uploads\\\/2022\\\/06\\\/10001-1.png\",\"width\":492,\"height\":250,\"caption\":\"Trumonytechs\"},\"image\":{\"@id\":\"https:\\\/\\\/www.trumonytechs.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/trumonytechs\\\/\",\"https:\\\/\\\/x.com\\\/Trumonytechs\",\"https:\\\/\\\/www.youtube.com\\\/channel\\\/UC2SyZohc9uTwFxzdTMLLlhw\",\"https:\\\/\\\/www.linkedin.com\\\/company\\\/81891179\\\/\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.trumonytechs.com\\\/#\\\/schema\\\/person\\\/eb4f36f93231f994effde9f9223a8c7b\",\"name\":\"Trumonytechs\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"sv-SE\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/445be3cb03a359def23944fc922a17ae56a3eab013b1959243c75737563ea1de?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/445be3cb03a359def23944fc922a17ae56a3eab013b1959243c75737563ea1de?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/445be3cb03a359def23944fc922a17ae56a3eab013b1959243c75737563ea1de?s=96&d=mm&r=g\",\"caption\":\"Trumonytechs\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Hur man v\u00e4ljer en konfiguration f\u00f6r batterilagringssystem","description":"How to choose a battery energy storage system configuration: weigh duty cycle, C-rate, cooling route, and UL 9540A before comparing supplier quotes.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.trumonytechs.com\/sv\/systemlosningar-for-lagring-av-batterienergi\/","og_locale":"sv_SE","og_type":"article","og_title":"How to Choose a Battery Energy Storage System Configuration","og_description":"How to choose a battery energy storage system configuration: weigh duty cycle, C-rate, cooling route, and UL 9540A before comparing supplier quotes.","og_url":"https:\/\/www.trumonytechs.com\/sv\/systemlosningar-for-lagring-av-batterienergi\/","og_site_name":"Trumonytechs","article_publisher":"https:\/\/www.facebook.com\/trumonytechs\/","article_published_time":"2026-09-30T01:38:10+00:00","og_image":[{"width":800,"height":600,"url":"https:\/\/www.trumonytechs.com\/wp-content\/uploads\/2026\/09\/bess-configuration-utility-scale-hero.webp","type":"image\/webp"}],"author":"Trumonytechs","twitter_card":"summary_large_image","twitter_creator":"@Trumonytechs","twitter_site":"@Trumonytechs","twitter_misc":{"Skriven av":"Trumonytechs","Ber\u00e4knad l\u00e4stid":"7 minuter"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.trumonytechs.com\/battery-energy-storage-system-solutions\/#article","isPartOf":{"@id":"https:\/\/www.trumonytechs.com\/battery-energy-storage-system-solutions\/"},"author":{"name":"Trumonytechs","@id":"https:\/\/www.trumonytechs.com\/#\/schema\/person\/eb4f36f93231f994effde9f9223a8c7b"},"headline":"How to Choose a Battery Energy Storage System Configuration","datePublished":"2026-09-30T01:38:10+00:00","mainEntityOfPage":{"@id":"https:\/\/www.trumonytechs.com\/battery-energy-storage-system-solutions\/"},"wordCount":2539,"commentCount":0,"publisher":{"@id":"https:\/\/www.trumonytechs.com\/#organization"},"image":{"@id":"https:\/\/www.trumonytechs.com\/battery-energy-storage-system-solutions\/#primaryimage"},"thumbnailUrl":"https:\/\/www.trumonytechs.com\/wp-content\/uploads\/2026\/09\/bess-configuration-utility-scale-hero.webp","keywords":["Battery Cooling","Battery Pack Cooling","Battery Thermal Management","Ev Battery Cooling","Liquid cold plate"],"articleSection":["Trumonytechs News"],"inLanguage":"sv-SE","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.trumonytechs.com\/battery-energy-storage-system-solutions\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.trumonytechs.com\/battery-energy-storage-system-solutions\/","url":"https:\/\/www.trumonytechs.com\/battery-energy-storage-system-solutions\/","name":"Hur man v\u00e4ljer en konfiguration f\u00f6r batterilagringssystem","isPartOf":{"@id":"https:\/\/www.trumonytechs.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.trumonytechs.com\/battery-energy-storage-system-solutions\/#primaryimage"},"image":{"@id":"https:\/\/www.trumonytechs.com\/battery-energy-storage-system-solutions\/#primaryimage"},"thumbnailUrl":"https:\/\/www.trumonytechs.com\/wp-content\/uploads\/2026\/09\/bess-configuration-utility-scale-hero.webp","datePublished":"2026-09-30T01:38:10+00:00","description":"How to choose a battery energy storage system configuration: weigh duty cycle, C-rate, cooling route, and UL 9540A before comparing supplier quotes.","breadcrumb":{"@id":"https:\/\/www.trumonytechs.com\/battery-energy-storage-system-solutions\/#breadcrumb"},"inLanguage":"sv-SE","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.trumonytechs.com\/battery-energy-storage-system-solutions\/"]}]},{"@type":"ImageObject","inLanguage":"sv-SE","@id":"https:\/\/www.trumonytechs.com\/battery-energy-storage-system-solutions\/#primaryimage","url":"https:\/\/www.trumonytechs.com\/wp-content\/uploads\/2026\/09\/bess-configuration-utility-scale-hero.webp","contentUrl":"https:\/\/www.trumonytechs.com\/wp-content\/uploads\/2026\/09\/bess-configuration-utility-scale-hero.webp","width":800,"height":600,"caption":"Outdoor utility-scale battery energy storage system enclosures sized to a duty cycle and site footprint"},{"@type":"BreadcrumbList","@id":"https:\/\/www.trumonytechs.com\/battery-energy-storage-system-solutions\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.trumonytechs.com\/"},{"@type":"ListItem","position":2,"name":"How to Choose a Battery Energy Storage System Configuration"}]},{"@type":"WebSite","@id":"https:\/\/www.trumonytechs.com\/#website","url":"https:\/\/www.trumonytechs.com\/","name":"Trumonytechs","description":"Systeml\u00f6sningar f\u00f6r v\u00e4rmehantering","publisher":{"@id":"https:\/\/www.trumonytechs.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.trumonytechs.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"sv-SE"},{"@type":"Organization","@id":"https:\/\/www.trumonytechs.com\/#organization","name":"Trumonytechs","url":"https:\/\/www.trumonytechs.com\/","logo":{"@type":"ImageObject","inLanguage":"sv-SE","@id":"https:\/\/www.trumonytechs.com\/#\/schema\/logo\/image\/","url":"https:\/\/www.trumonytechs.com\/wp-content\/uploads\/2022\/06\/10001-1.png","contentUrl":"https:\/\/www.trumonytechs.com\/wp-content\/uploads\/2022\/06\/10001-1.png","width":492,"height":250,"caption":"Trumonytechs"},"image":{"@id":"https:\/\/www.trumonytechs.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/trumonytechs\/","https:\/\/x.com\/Trumonytechs","https:\/\/www.youtube.com\/channel\/UC2SyZohc9uTwFxzdTMLLlhw","https:\/\/www.linkedin.com\/company\/81891179\/"]},{"@type":"Person","@id":"https:\/\/www.trumonytechs.com\/#\/schema\/person\/eb4f36f93231f994effde9f9223a8c7b","name":"Trumonytechs","image":{"@type":"ImageObject","inLanguage":"sv-SE","@id":"https:\/\/secure.gravatar.com\/avatar\/445be3cb03a359def23944fc922a17ae56a3eab013b1959243c75737563ea1de?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/445be3cb03a359def23944fc922a17ae56a3eab013b1959243c75737563ea1de?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/445be3cb03a359def23944fc922a17ae56a3eab013b1959243c75737563ea1de?s=96&d=mm&r=g","caption":"Trumonytechs"}}]}},"_links":{"self":[{"href":"https:\/\/www.trumonytechs.com\/sv\/wp-json\/wp\/v2\/posts\/26393","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.trumonytechs.com\/sv\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.trumonytechs.com\/sv\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.trumonytechs.com\/sv\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.trumonytechs.com\/sv\/wp-json\/wp\/v2\/comments?post=26393"}],"version-history":[{"count":0,"href":"https:\/\/www.trumonytechs.com\/sv\/wp-json\/wp\/v2\/posts\/26393\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.trumonytechs.com\/sv\/wp-json\/wp\/v2\/media\/37953"}],"wp:attachment":[{"href":"https:\/\/www.trumonytechs.com\/sv\/wp-json\/wp\/v2\/media?parent=26393"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.trumonytechs.com\/sv\/wp-json\/wp\/v2\/categories?post=26393"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.trumonytechs.com\/sv\/wp-json\/wp\/v2\/tags?post=26393"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}