{"id":25436,"date":"2025-01-17T00:14:01","date_gmt":"2025-01-17T00:14:01","guid":{"rendered":"https:\/\/trumonytechs.com\/?page_id=25436"},"modified":"2026-09-27T00:21:45","modified_gmt":"2026-09-27T00:21:45","slug":"termisk-hantering-av-batteripaket","status":"publish","type":"page","link":"https:\/\/www.trumonytechs.com\/sv\/battery-pack-thermal-management\/","title":{"rendered":"Termisk hantering av batteripaket"},"content":{"rendered":"<main class=\"trumo-scope\"> <section class=\"trumo-hero trumo-blueprint\" data-cta=\"hero\"> <div class=\"trumo-wrap trumo-hero-inner\"> <div class=\"trumo-hero-left\"> <div class=\"trumo-hcats\"><span class=\"trumo-hcat trumo-hcat--solid\">EV- och ESS-batteripaket<\/span> <span class=\"trumo-hcat trumo-hcat--ghost\">Cold plates, manifolds, TIM<\/span><\/div> <h1>Custom Battery Pack Thermal Management Components for EV &amp; ESS<\/h1> <p class=\"trumo-hero-lead\">Battery pack thermal management from Trumonytechs covers the heat path from cell to coolant: liquid cold plates, cooling tubes, manifolds and thermal interface materials, with CFD review before tooling. The cold plate configuration depends on cell format and heat load, and the TIM family on its use in the pack. We supply cold plates and cooling components built to your cell format, from prototype to volume production, alongside TIM from listed model ranges.<\/p> <p class=\"trumo-hero-note\">Start with your cell format and peak heat load: cell format sets the cold plate configuration, and heat load sizes the flow path.<\/p> <div class=\"trumo-hero-btns\"> <a class=\"trumo-btn trumo-btn--primary\" href=\"mailto:oversea@trumonytechs.com?subject=Battery%20pack%20thermal%20management%20inquiry\">Email Your Pack Details<\/a> <button type=\"button\" class=\"trumo-btn trumo-btn--ghost trumo-quote-open\" popovertarget=\"trumo-quote\" aria-haspopup=\"dialog\">Beg\u00e4r en offert<\/button> <\/div> <\/div> <figure class=\"trumo-hero-fig trumo-hero-fig--photo\"> <span class=\"trumo-corner trumo-corner--tl\"><\/span><span class=\"trumo-corner trumo-corner--tr\"><\/span><span class=\"trumo-corner trumo-corner--bl\"><\/span><span class=\"trumo-corner trumo-corner--br\"><\/span> <img src=\"https:\/\/www.trumonytechs.com\/wp-content\/uploads\/2026\/03\/ev-battery-pack-cold-plate.webp\" alt=\"EV-batterimoduler monterade p\u00e5 en kall platta av aluminium\" width=\"768\" height=\"573\" fetchpriority=\"high\" decoding=\"async\"> <\/figure> <\/div> <\/section> <div class=\"trumo-wrap\"> <section class=\"trumo-sec\"> <div class=\"trumo-sechead\" aria-hidden=\"true\"><span class=\"trumo-secno\">01<\/span><span class=\"trumo-secline\"><\/span><\/div> <h2>When a Battery Pack Needs Liquid Cooling \u2014 and When Air Is Enough<\/h2> <p class=\"trumo-lede\">Liquid cooling earns its place in a battery pack when cell-to-cell \u0394T has to stay below 3\u20135 \u00b0C, or when heat load per unit area rises past what air can carry away. High C-rate cycling and outdoor, containerized or utility-scale energy storage usually fall on the liquid side of that line.<\/p> <div class=\"trumo-stat\"><div class=\"trumo-stat-n\">3\u20135 \u00b0C<\/div><p class=\"trumo-stat-t\">Cell-to-cell \u0394T target below which liquid cooling outperforms air.<\/p><\/div> <figure class=\"trumo-fig trumo-fig--scroll trumo-fig--wide\"> <svg viewbox=\"0 0 960 184\" role=\"img\" aria-label=\"Heat path: cells, TIM, cold plate, manifolds and tubes supplied by Trumonytechs; pump and heat exchanger usually from the system supplier\"><path d=\"M206 34 V24 a2 2 0 0 1 2 -2 H752 a2 2 0 0 1 2 2 V34\" fill=\"none\" stroke=\"#FD7000\" stroke-width=\"2\"\/><rect x=\"8\" y=\"40\" width=\"176\" height=\"140\" rx=\"3\" fill=\"#FFFFFF\" stroke=\"#E5E7EB\"\/><path d=\"M8 43 a3 3 0 0 1 3 -3 h170 a3 3 0 0 1 3 3 z\" fill=\"#1E1E1E\"\/><g transform=\"translate(22 54) scale(.9)\"><g fill=\"none\" stroke=\"#5F6B7A\" stroke-width=\"1.8\" stroke-linecap=\"round\" stroke-linejoin=\"round\"><rect x=\"6\" y=\"11\" width=\"8\" height=\"23\" rx=\"1.5\"\/><rect x=\"16\" y=\"11\" width=\"8\" height=\"23\" rx=\"1.5\"\/><rect x=\"26\" y=\"11\" width=\"8\" height=\"23\" rx=\"1.5\"\/><path d=\"M10 11 V8 M20 11 V8 M30 11 V8\"\/><\/g><path d=\"M8 4 q2 -2 4 0 t4 0 M24 4 q2 -2 4 0 t4 0\" fill=\"none\" stroke=\"#FD7000\" stroke-width=\"1.4\" stroke-linecap=\"round\"\/><\/g><text x=\"22\" y=\"110\" font-size=\"14\" font-weight=\"700\" fill=\"#1E1E1E\">Celler<\/text><text x=\"22\" y=\"130\" font-size=\"13\" fill=\"#5F6B7A\">v\u00e4rmek\u00e4lla<\/text><path d=\"M189.5 105 L194.5 110 L189.5 115\" fill=\"none\" stroke=\"#767676\" stroke-width=\"2\" stroke-linecap=\"round\" stroke-linejoin=\"round\"\/><rect x=\"200\" y=\"40\" width=\"176\" height=\"140\" rx=\"3\" fill=\"#FFF5ED\" stroke=\"#FEDEBF\"\/><path d=\"M200 43 a3 3 0 0 1 3 -3 h170 a3 3 0 0 1 3 3 z\" fill=\"#FD7000\"\/><g transform=\"translate(214 54) scale(.9)\"><g fill=\"none\" stroke=\"#FD7000\" stroke-width=\"1.8\" stroke-linejoin=\"round\"><rect x=\"6\" y=\"7\" width=\"28\" height=\"11\" rx=\"1.5\"\/><rect x=\"6\" y=\"26\" width=\"28\" height=\"8\" rx=\"1.5\"\/><\/g><rect x=\"6\" y=\"19.5\" width=\"28\" height=\"5\" fill=\"#FCAE00\"\/><\/g><text x=\"214\" y=\"110\" font-size=\"14\" font-weight=\"700\" fill=\"#1E1E1E\">TID<\/text><text x=\"214\" y=\"130\" font-size=\"13\" fill=\"#5F6B7A\">fills the cell-to-plate gap<\/text><path d=\"M381.5 105 L386.5 110 L381.5 115\" fill=\"none\" stroke=\"#767676\" stroke-width=\"2\" stroke-linecap=\"round\" stroke-linejoin=\"round\"\/><rect x=\"392\" y=\"40\" width=\"176\" height=\"140\" rx=\"3\" fill=\"#FFF5ED\" stroke=\"#FEDEBF\"\/><path d=\"M392 43 a3 3 0 0 1 3 -3 h170 a3 3 0 0 1 3 3 z\" fill=\"#FD7000\"\/><g transform=\"translate(406 54) scale(.9)\"><rect x=\"5\" y=\"10\" width=\"30\" height=\"20\" rx=\"2\" fill=\"none\" stroke=\"#FD7000\" stroke-width=\"1.8\"\/><g stroke=\"#FD7000\" stroke-width=\"2.2\" stroke-linecap=\"round\"><path d=\"M10 15.5 H30 M10 20 H30 M10 24.5 H30\"\/><\/g><\/g><text x=\"406\" y=\"110\" font-size=\"14\" font-weight=\"700\" fill=\"#1E1E1E\">Kall platta<\/text><text x=\"406\" y=\"130\" font-size=\"13\" fill=\"#5F6B7A\">absorbs heat into coolant<\/text><path d=\"M573.5 105 L578.5 110 L573.5 115\" fill=\"none\" stroke=\"#767676\" stroke-width=\"2\" stroke-linecap=\"round\" stroke-linejoin=\"round\"\/><rect x=\"584\" y=\"40\" width=\"176\" height=\"140\" rx=\"3\" fill=\"#FFF5ED\" stroke=\"#FEDEBF\"\/><path d=\"M584 43 a3 3 0 0 1 3 -3 h170 a3 3 0 0 1 3 3 z\" fill=\"#FD7000\"\/><g transform=\"translate(598 54) scale(.9)\"><g fill=\"none\" stroke=\"#FD7000\" stroke-linecap=\"round\" stroke-linejoin=\"round\"><path d=\"M5 11 H35\" stroke-width=\"3.6\"\/><path d=\"M11 12 V33 M20 12 V33 M29 12 V33\" stroke-width=\"1.8\"\/><\/g><g fill=\"#FCAE00\"><circle cx=\"11\" cy=\"11\" r=\"1.8\"\/><circle cx=\"20\" cy=\"11\" r=\"1.8\"\/><circle cx=\"29\" cy=\"11\" r=\"1.8\"\/><\/g><\/g><text x=\"598\" y=\"110\" font-size=\"14\" font-weight=\"700\" fill=\"#1E1E1E\">Grenr\u00f6r och r\u00f6r<\/text><text x=\"598\" y=\"130\" font-size=\"13\" fill=\"#5F6B7A\">f\u00f6rdela kylv\u00e4tskan<\/text><path d=\"M765.5 105 L770.5 110 L765.5 115\" fill=\"none\" stroke=\"#767676\" stroke-width=\"2\" stroke-linecap=\"round\" stroke-linejoin=\"round\"\/><rect x=\"776\" y=\"40\" width=\"176\" height=\"140\" rx=\"3\" fill=\"#FFFFFF\" stroke=\"#C2C7CC\" stroke-dasharray=\"4 3\"\/><g transform=\"translate(790 54) scale(.9)\"><g fill=\"none\" stroke=\"#5F6B7A\" stroke-width=\"1.8\" stroke-linecap=\"round\" stroke-linejoin=\"round\"><circle cx=\"12\" cy=\"20\" r=\"8\"\/><path d=\"M12 20 L12 13 M12 20 L18 23.5 M12 20 L6 23.5\"\/><path d=\"M24 9 V31 M28.5 9 V31 M33 9 V31 M22 20 H35\"\/><\/g><\/g><text x=\"790\" y=\"110\" font-size=\"14\" font-weight=\"700\" fill=\"#1E1E1E\">Pump and heat<\/text><text x=\"790\" y=\"128\" font-size=\"14\" font-weight=\"700\" fill=\"#1E1E1E\">exchanger<\/text><text x=\"790\" y=\"148\" font-size=\"13\" fill=\"#5F6B7A\">usually your system<\/text><text x=\"790\" y=\"165\" font-size=\"13\" fill=\"#5F6B7A\">supplier<\/text><\/svg> <figcaption class=\"trumo-cap\">Trumonytechs supplies the TIM, cold plate and manifold stages; the pump and external heat exchanger are typically sourced from your system supplier.<\/figcaption> <\/figure> <ul class=\"trumo-checks\"> <li><span class=\"n\" aria-hidden=\"true\">01<\/span><div><b>Passive cooling already works<\/b><p>Natural convection or a heat sink keeps cells inside their temperature limits.<\/p><\/div><\/li> <li><span class=\"n\" aria-hidden=\"true\">02<\/span><div><b>No room for a coolant loop<\/b><p>The system cannot host the pump, reservoir and heat exchanger a liquid loop needs.<\/p><\/div><\/li> <li><span class=\"n\" aria-hidden=\"true\">03<\/span><div><b>Incompatible working fluid<\/b><p>The fluid in the loop is not compatible with aluminum or copper.<\/p><\/div><\/li> <\/ul> <p>Where any of these conditions holds, or a lower-density backup system runs at moderate ambient temperatures, air or passive cooling may be enough. We confirm that at the first technical review instead of defaulting to a more complex solution. Scale-specific requirements for grid, C&amp;I and solar-plus-storage projects are covered on the <a href=\"https:\/\/www.trumonytechs.com\/sv\/ess-cooling-solutions\/\">ESS-kyll\u00f6sningar<\/a> sida.<\/p> <\/section> <div class=\"trumo-rule\"><i><\/i><\/div> <section class=\"trumo-sec\"> <div class=\"trumo-sechead\" aria-hidden=\"true\"><span class=\"trumo-secno\">02<\/span><span class=\"trumo-secline\"><\/span><\/div> <h2>Battery Pack Thermal Management Components: Cold Plates, Tubes and TIM<\/h2> <p class=\"trumo-lede\">Battery pack components from Trumonytechs fall into four families, and which cold plate construction a pack uses depends on its cell format. Cold plates and TIM have their own product pages, manifolds are covered on the ESS cooling page, and the design review is described below.<\/p> <ul class=\"trumo-postgrid trumo-postgrid--cols-3\" role=\"list\"><li class=\"trumo-postgrid-item\"><div class=\"trumo-postgrid-fig\"><img width=\"600\" height=\"600\" src=\"https:\/\/www.trumonytechs.com\/wp-content\/uploads\/2022\/09\/Water-Cooling-Plates.jpg\" class=\"attachment-medium_large size-medium_large\" alt=\"Vattenkylningsplattor - material f\u00f6r kylning av batteripaket\" loading=\"lazy\" decoding=\"async\" sizes=\"auto, (max-width: 900px) 50vw, 340px\" srcset=\"https:\/\/www.trumonytechs.com\/wp-content\/uploads\/2022\/09\/Water-Cooling-Plates.jpg 600w, https:\/\/www.trumonytechs.com\/wp-content\/uploads\/2022\/09\/Water-Cooling-Plates-300x300.jpg 300w, https:\/\/www.trumonytechs.com\/wp-content\/uploads\/2022\/09\/Water-Cooling-Plates-150x150.jpg 150w, https:\/\/www.trumonytechs.com\/wp-content\/uploads\/2022\/09\/Water-Cooling-Plates-256x256.jpg 256w\" \/><\/div><div class=\"trumo-postgrid-body\"><h3 class=\"trumo-postgrid-title\"><a href=\"https:\/\/www.trumonytechs.com\/sv\/pf\/water-cooling-plate\/\">Vattenkylningsplattor (EV&amp;ESS)<\/a><\/h3><\/div><\/li><li class=\"trumo-postgrid-item\"><div class=\"trumo-postgrid-fig\"><img width=\"768\" height=\"576\" src=\"https:\/\/www.trumonytechs.com\/wp-content\/uploads\/2022\/07\/10006-768x576.jpg\" class=\"attachment-medium_large size-medium_large\" alt=\"Elektriskt isolerande dyna-trumonytechs\" loading=\"lazy\" decoding=\"async\" sizes=\"auto, (max-width: 900px) 50vw, 340px\" srcset=\"https:\/\/www.trumonytechs.com\/wp-content\/uploads\/2022\/07\/10006-768x576.jpg 768w, https:\/\/www.trumonytechs.com\/wp-content\/uploads\/2022\/07\/10006-300x225.jpg 300w, https:\/\/www.trumonytechs.com\/wp-content\/uploads\/2022\/07\/10006.jpg 800w\" \/><\/div><div class=\"trumo-postgrid-body\"><h3 class=\"trumo-postgrid-title\"><a href=\"https:\/\/www.trumonytechs.com\/sv\/pf\/thermal-conductive-pad\/\">Termiskt ledande platta<\/a><\/h3><\/div><\/li><li class=\"trumo-postgrid-item\"><div class=\"trumo-postgrid-fig\"><img width=\"768\" height=\"768\" src=\"https:\/\/www.trumonytechs.com\/wp-content\/uploads\/2022\/07\/Thermal-Conductive-Gel-768x768.jpg\" class=\"attachment-medium_large size-medium_large\" alt=\"Termiskt ledande gel - termiskt ledande material\" loading=\"lazy\" decoding=\"async\" sizes=\"auto, (max-width: 900px) 50vw, 340px\" srcset=\"https:\/\/www.trumonytechs.com\/wp-content\/uploads\/2022\/07\/Thermal-Conductive-Gel-768x768.jpg 768w, https:\/\/www.trumonytechs.com\/wp-content\/uploads\/2022\/07\/Thermal-Conductive-Gel-300x300.jpg 300w, https:\/\/www.trumonytechs.com\/wp-content\/uploads\/2022\/07\/Thermal-Conductive-Gel-150x150.jpg 150w, https:\/\/www.trumonytechs.com\/wp-content\/uploads\/2022\/07\/Thermal-Conductive-Gel-256x256.jpg 256w, https:\/\/www.trumonytechs.com\/wp-content\/uploads\/2022\/07\/Thermal-Conductive-Gel.jpg 800w\" \/><\/div><div class=\"trumo-postgrid-body\"><h3 class=\"trumo-postgrid-title\"><a href=\"https:\/\/www.trumonytechs.com\/sv\/pf\/thermal-conductive-gel\/\">V\u00e4rmeledande gel<\/a><\/h3><\/div><\/li><li class=\"trumo-postgrid-item\"><div class=\"trumo-postgrid-fig\"><img width=\"750\" height=\"519\" src=\"https:\/\/www.trumonytechs.com\/wp-content\/uploads\/2022\/07\/HTB1X8Nwerus3KVjSZKbq6xqkFXaQ.jpg\" class=\"attachment-medium_large size-medium_large\" alt=\"POTTING GLUE - Material f\u00f6r termiskt gr\u00e4nssnitt\" loading=\"lazy\" decoding=\"async\" sizes=\"auto, (max-width: 900px) 50vw, 340px\" srcset=\"https:\/\/www.trumonytechs.com\/wp-content\/uploads\/2022\/07\/HTB1X8Nwerus3KVjSZKbq6xqkFXaQ.jpg 750w, https:\/\/www.trumonytechs.com\/wp-content\/uploads\/2022\/07\/HTB1X8Nwerus3KVjSZKbq6xqkFXaQ-300x208.jpg 300w\" \/><\/div><div class=\"trumo-postgrid-body\"><h3 class=\"trumo-postgrid-title\"><a href=\"https:\/\/www.trumonytechs.com\/sv\/pf\/potting-glue\/\">Gjutmassa<\/a><\/h3><\/div><\/li><li class=\"trumo-postgrid-item\"><div class=\"trumo-postgrid-fig\"><img width=\"768\" height=\"768\" src=\"https:\/\/www.trumonytechs.com\/wp-content\/uploads\/2022\/07\/THERMAL-CONDUCTIVE-STRUCTURAL-ADHESIVE-768x768.webp\" class=\"attachment-medium_large size-medium_large\" alt=\"Termiskt ledande silikonfett-trumonytechs\" loading=\"lazy\" decoding=\"async\" sizes=\"auto, (max-width: 900px) 50vw, 340px\" srcset=\"https:\/\/www.trumonytechs.com\/wp-content\/uploads\/2022\/07\/THERMAL-CONDUCTIVE-STRUCTURAL-ADHESIVE-768x768.webp 768w, https:\/\/www.trumonytechs.com\/wp-content\/uploads\/2022\/07\/THERMAL-CONDUCTIVE-STRUCTURAL-ADHESIVE-300x300.webp 300w, https:\/\/www.trumonytechs.com\/wp-content\/uploads\/2022\/07\/THERMAL-CONDUCTIVE-STRUCTURAL-ADHESIVE-150x150.webp 150w, https:\/\/www.trumonytechs.com\/wp-content\/uploads\/2022\/07\/THERMAL-CONDUCTIVE-STRUCTURAL-ADHESIVE-256x256.webp 256w, https:\/\/www.trumonytechs.com\/wp-content\/uploads\/2022\/07\/THERMAL-CONDUCTIVE-STRUCTURAL-ADHESIVE.webp 960w\" \/><\/div><div class=\"trumo-postgrid-body\"><h3 class=\"trumo-postgrid-title\"><a href=\"https:\/\/www.trumonytechs.com\/sv\/pf\/thermal-conductive-structural-adhesive\/\">Termiskt ledande strukturellt lim<\/a><\/h3><\/div><\/li><li class=\"trumo-postgrid-item\"><div class=\"trumo-postgrid-fig\"><img width=\"600\" height=\"600\" src=\"https:\/\/www.trumonytechs.com\/wp-content\/uploads\/2022\/07\/Thermally-Conductive-Silicone-Grease4.jpg\" class=\"attachment-medium_large size-medium_large\" alt=\"Termiskt ledande silikonfett - termiskt ledande material\" loading=\"lazy\" decoding=\"async\" sizes=\"auto, (max-width: 900px) 50vw, 340px\" srcset=\"https:\/\/www.trumonytechs.com\/wp-content\/uploads\/2022\/07\/Thermally-Conductive-Silicone-Grease4.jpg 600w, https:\/\/www.trumonytechs.com\/wp-content\/uploads\/2022\/07\/Thermally-Conductive-Silicone-Grease4-300x300.jpg 300w, https:\/\/www.trumonytechs.com\/wp-content\/uploads\/2022\/07\/Thermally-Conductive-Silicone-Grease4-150x150.jpg 150w, https:\/\/www.trumonytechs.com\/wp-content\/uploads\/2022\/07\/Thermally-Conductive-Silicone-Grease4-256x256.jpg 256w\" \/><\/div><div class=\"trumo-postgrid-body\"><h3 class=\"trumo-postgrid-title\"><a href=\"https:\/\/www.trumonytechs.com\/sv\/pf\/thermal-conductive-silicone-grease\/\">Termiskt ledande silikonfett<\/a><\/h3><\/div><\/li><\/ul> <\/section> <div class=\"trumo-rule\"><i><\/i><\/div> <section class=\"trumo-sec\"> <div class=\"trumo-sechead\" aria-hidden=\"true\"><span class=\"trumo-secno\">03<\/span><span class=\"trumo-secline\"><\/span><\/div> <h2>Matching Cold Plate and TIM to Cell Format and Joint Type<\/h2> <p class=\"trumo-lede\">Cold plate configurations are listed by cell format, and TIM families by the joint they serve: gap filling, cell-to-plate bonding or module potting. Plates use 3003 or 1060 aluminum or copper, while the TIM families use silicone, epoxy or polyurethane chemistry.<\/p> <div class=\"trumo-tablewrap\"> <table> <thead><tr><th scope=\"col\">Cell format \/ joint<\/th><th scope=\"col\">Cold plate configuration<\/th><th scope=\"col\">TIM-familjen<\/th><th scope=\"col\">Kemi<\/th><th scope=\"col\">Selection note<\/th><\/tr><\/thead> <tbody> <tr><td>Prismatiska celler<\/td><td>Microchannel, for large-area uniformity<\/td><td>Gap pad 30101, unreinforced<\/td><td>Silikon<\/td><td>Unreinforced pad recommended up to 300 \u00d7 200 mm<\/td><\/tr> <tr><td>P\u00e5seceller<\/td><td>Microchannel, for large-area uniformity<\/td><td>No pouch-specific TIM recommendation is published<\/td><td>\u2014<\/td><td>TIM reviewed in the thermal design discussion<\/td><\/tr> <tr><td>Cylindrical modules (18650 \/ 2170 \/ 4680)<\/td><td>Snake tube, where routing space is tight<\/td><td>Gap pad 30101 with PI film or glass-fiber reinforcement<\/td><td>Silikon<\/td><td>Reinforcement adds body strength<\/td><\/tr> <tr><td>Large-area plates at production volume (EV \/ ESS)<\/td><td>St\u00e4mplat<\/td><td>\u2014<\/td><td>\u2014<\/td><td>Needs a dedicated die; higher production MOQ threshold than CNC or FSW parts<\/td><\/tr> <tr><td>Celler bundna till den kalla plattan<\/td><td>\u2014<\/td><td>Polyurethane structural adhesive 30107<\/td><td>Polyuretan<\/td><td>Fullst\u00e4ndig h\u00e4rdning 7 dagar vid 23 \u00b1 2 \u00b0C<\/td><\/tr> <tr><td>Modulfyllning, isolering och ingjutning<\/td><td>\u2014<\/td><td>Silicone potting compound 30103<\/td><td>Silikon<\/td><td>Hand-mixed A\/B; room or elevated temperature cure<\/td><\/tr> <\/tbody> <\/table> <\/div> <p>Within the pad family, reinforcement trades conductivity for handling. An unreinforced pad conducts heat better and costs less, but it is weak, tacks poorly, deforms in large pieces and is hard to place without trapped air. For pieces within 300 \u00d7 200 mm, the unreinforced pad is the lower-cost option. PI-film and PI-tape structures are recommended up to 500 \u00d7 420 mm; PI tape also adds insulation and a stronger bond to the plate, and may reduce manual placement cost.<\/p> <div class=\"trumo-callout\"><p>Keep aluminum and copper parts out of the same coolant loop, and validate coolant chemistry early: certain glycol concentrations accelerate corrosion in certain alloy grades.<\/p><\/div> <\/section> <div class=\"trumo-rule\"><i><\/i><\/div> <section class=\"trumo-sec\"> <div class=\"trumo-sechead\" aria-hidden=\"true\"><span class=\"trumo-secno\">04<\/span><span class=\"trumo-secline\"><\/span><\/div> <h2>Where the Cold Plate Meets the TIM: Interface and Supply Scope<\/h2> <p class=\"trumo-lede\">Contact resistance between cell, TIM and cold plate sits with one supplier when both parts come from Trumonytechs. Pads and gels also insulate electrically, with breakdown voltages from above 6 to above 12 kV\/mm across listed pad models and 8 kV\/mm for gels.<\/p> <div class=\"trumo-pair\"> <div><b>What we supply on the heat path<\/b><p>The scope covers cold plates, snake tubes, liquid distribution manifolds, brazed cooling assemblies and the five TIM families, with DFM feedback included in the quote at no extra charge. We review interface material selection inside the thermal design discussion at no additional cost.<\/p><\/div> <div><b>What usually stays with your system supplier<\/b><p>Pumps and external heat exchangers are typically sourced from your system integrator or BOS supplier. We advise on how our parts integrate with them during the thermal design review.<\/p><\/div> <\/div> <\/section> <\/div> <section class=\"trumo-band trumo-blueprint\"> <div class=\"trumo-wrap\"> <div class=\"trumo-sechead\" aria-hidden=\"true\"><span class=\"trumo-secno\">05<\/span><span class=\"trumo-secline\"><\/span><\/div> <h2>From Thermal Design Review to Volume Production<\/h2> <p class=\"trumo-lede\">Custom cold plate and cooling component development runs in five stages, with a client confirmation point at each one. No tooling or fabrication starts until your engineering team has approved the simulation outputs.<\/p> <p>The thermal design review starts from the six inputs below. If some are still open, share what is confirmed, and the review identifies which variables need resolving before scoping continues. TIM selection enters at this review as an input; the five stages apply to the cold plate and cooling components.<\/p> <ol class=\"trumo-chips\"> <li>Cell format and pack layout<\/li> <li>Heat load and duty cycle, peak and continuous<\/li> <li>Maximum cell temperature and cell-to-cell \u0394T target<\/li> <li>Coolant type and inlet temperature<\/li> <li>Flow range and allowable pressure drop<\/li> <li>Mechanical envelope, interface limits and TIM constraints<\/li> <\/ol> <ol class=\"trumo-timeline\"> <li class=\"trumo-step\"><div class=\"n\">Klienten bekr\u00e4ftar inmatningar<\/div><b>Granskning av termisk design<\/b><p>Cell format, heat load, temperature targets and pack geometry checked for feasibility before any design work.<\/p><\/li> <li class=\"trumo-step\"><div class=\"n\">Kundrecensioners resultat<\/div><b>CFD-simulering<\/b><p>Flow distribution, temperature uniformity and pressure drop under defined inlet conditions.<\/p><\/li> <li class=\"trumo-step\"><div class=\"n\">Tidslinje bekr\u00e4ftad<\/div><b>Prototype build<\/b><p>Starts only after simulation sign-off; lead time set by plate type and geometry.<\/p><\/li> <li class=\"trumo-step\"><div class=\"n\">Klientsignering<\/div><b>Validering av prov<\/b><p>Leak and pressure testing, thermal resistance measurement and client-specific documentation.<\/p><\/li> <li class=\"trumo-step\"><div class=\"n\">Produktionen b\u00f6rjar<\/div><b>Volymproduktion<\/b><p>Released only after the validated sample is signed off.<\/p><\/li> <\/ol> <p>Development validation also covers mechanical load, flow resistance, internal corrosion and salt spray corrosion. The reasoning behind flow paths, coolant choice and validation is set out in our <a href=\"https:\/\/www.trumonytechs.com\/sv\/liquid-cooling-system-design\/\">liquid cooling system design guide<\/a>.<\/p> <\/div> <\/section> <div class=\"trumo-wrap\"> <section class=\"trumo-sec\"> <div class=\"trumo-sechead\" aria-hidden=\"true\"><span class=\"trumo-secno\">06<\/span><span class=\"trumo-secline\"><\/span><\/div> <h2>Cold Plate and TIM Pricing: Tooling, MOQ and Quote Scope<\/h2> <p>Process choice sets the tooling and MOQ picture for a cold plate: CNC-machined prototypes need no tooling, while stamped plates need a dedicated die and carry a higher production MOQ threshold. Cold plate selection also weighs heat load, plate size, available space, production volume and cost, and no price range is published on this page. Whether a tooling charge applies, and how it is calculated, is not published either; TIM is quoted by model, quantity and packaging format.<\/p> <div class=\"trumo-cta\" data-cta=\"mid\"> <p>Send heat load and expected annual volume with your drawing; DFM feedback comes back with the quote at no extra charge.<\/p> <div class=\"trumo-cta-btns\"> <a class=\"trumo-btn trumo-btn--primary\" href=\"mailto:oversea@trumonytechs.com?subject=Battery%20pack%20thermal%20management%20inquiry\">Email Drawing and Volume<\/a> <button type=\"button\" class=\"trumo-btn trumo-btn--ghost trumo-quote-open\" popovertarget=\"trumo-quote\" aria-haspopup=\"dialog\">Beg\u00e4r en offert<\/button> <\/div> <\/div> <\/section> <div class=\"trumo-rule\"><i><\/i><\/div> <section class=\"trumo-sec\"> <div class=\"trumo-sechead\" aria-hidden=\"true\"><span class=\"trumo-secno\">07<\/span><span class=\"trumo-secline\"><\/span><\/div> <h2>Quality, Compliance and Delivery by Product Line<\/h2> <p class=\"trumo-lede\">Inspection, paperwork and lead times differ between cold plates and TIM, so each product line is summarized here and detailed on its own page. The table keeps the two compliance statements apart because they cover different materials.<\/p> <div class=\"trumo-tablewrap\"> <table> <thead><tr><th scope=\"col\">Punkt<\/th><th scope=\"col\">Kalla plattor och r\u00f6r<\/th><th scope=\"col\">Material f\u00f6r termiska gr\u00e4nssnitt<\/th><\/tr><\/thead> <tbody> <tr><td>Outgoing inspection<\/td><td>Helium leak test on every part; CMM check including thermal-interface flatness; hydrostatic burst above rated working pressure; FAI; SPC on key dimensions<\/td><td>Not published on this page; model data list test methods for measured properties where provided<\/td><\/tr> <tr><td>Compliance documents<\/td><td>RoHS \/ REACH declarations and SVHC communication on request; material composition supports IMDS submission<\/td><td>RoHS-compliant formulation; UL 94 V-0 flame rating where the model data lists it<\/td><\/tr> <tr><td>Quality system<\/td><td>Kvalitetssystemcertifikat (ISO 9001, IATF 16949) finns tillg\u00e4ngliga p\u00e5 beg\u00e4ran; specificera vilka du beh\u00f6ver i din f\u00f6rfr\u00e5gan.<\/td><td>Certificate scope for TIM production is not published on this page<\/td><\/tr> <tr><td>Prototype lead time<\/td><td>CNC prototypes usually 2\u20133 weeks after design confirmation; tooled prototypes longer, confirmed at design review<\/td><td>Not published on this page<\/td><\/tr> <tr><td>Documents and packaging<\/td><td>CoC, TDS, mill certificate and packing list; moisture-sealed packing with desiccant, port sealing plugs, wooden crates for large orders, batch traceability labels<\/td><td>Not published on this page<\/td><\/tr> <tr><td>Details<\/td><td>Vattenkylningsplattor<\/td><td><a href=\"https:\/\/www.trumonytechs.com\/sv\/material-for-termiska-granssnitt\/\">Material f\u00f6r termiska gr\u00e4nssnitt<\/a><\/td><\/tr> <\/tbody> <\/table> <\/div> <p class=\"trumo-note\">Where a cell reads \"not published\", state the lead time, documents or packaging information you need in your RFQ.<\/p> <p>Cold plate development can produce FAI reports, a CFD evaluation summary and sample validation documentation for supplier qualification, subject to project requirements. Cold plate process capability covers FSW, vacuum brazing, stamping, extrusion and CNC, and volume production is released only after the validated sample is signed off. Third-party inspection arrangements are not published on this page either.<\/p> <div class=\"trumo-photos trumo-photos--row4\"><span class=\"trumo-corner trumo-corner--tl\"><\/span><span class=\"trumo-corner trumo-corner--tr\"><\/span><span class=\"trumo-corner trumo-corner--bl\"><\/span><span class=\"trumo-corner trumo-corner--br\"><\/span> <img src=\"https:\/\/www.trumonytechs.com\/wp-content\/uploads\/2022\/09\/Sealability-test.jpg\" alt=\"T\u00e4tningsteststation f\u00f6r flytande kalla plattor\" width=\"700\" height=\"525\" loading=\"lazy\" decoding=\"async\"> <img src=\"https:\/\/www.trumonytechs.com\/wp-content\/uploads\/2026\/09\/liquid-cold-plate-packaging-moisture-barrier.webp\" alt=\"Flytande kylplatta i aluminium f\u00f6rseglad i en fuktsp\u00e4rrp\u00e5se med torkmedelsp\u00e5se och portpluggar, f\u00f6rpackad i ett skumfodrat tr\u00e4fodral\" width=\"800\" height=\"600\" loading=\"lazy\" decoding=\"async\"> <img src=\"https:\/\/www.trumonytechs.com\/wp-content\/uploads\/2026\/09\/tim-thermal-conductivity-test.webp\" alt=\"Transient plank\u00e4llarsensor fastkl\u00e4md mellan tv\u00e5 termiska dynprover f\u00f6r ett v\u00e4rmeledningsf\u00f6rm\u00e5gastest\" width=\"800\" height=\"533\" loading=\"lazy\" decoding=\"async\"> <img src=\"https:\/\/www.trumonytechs.com\/wp-content\/uploads\/2026\/09\/tim-ul94-vertical-burn-test.webp\" alt=\"Materialtestremsa fastkl\u00e4md vertikalt i en flamkammare under ett vertikalt br\u00e4nntest\" width=\"800\" height=\"533\" loading=\"lazy\" decoding=\"async\"> <\/div> <\/section> <div class=\"trumo-rule\"><i><\/i><\/div> <section class=\"trumo-sec\"> <div class=\"trumo-sechead\" aria-hidden=\"true\"><span class=\"trumo-secno\">08<\/span><span class=\"trumo-secline\"><\/span><\/div> <h2>Questions Engineers Ask About Pack Cooling Parts<\/h2> <div class=\"trumo-faq\"> <details><summary><span class=\"q\">Which inputs most often change late in a battery pack thermal management project?<\/span><span class=\"i\" aria-hidden=\"true\">+<\/span><\/summary><p>Coolant type and concentration, and coolant inlet temperature, are the two inputs most likely to shift after scoping. The water-glycol ratio affects conductivity, viscosity and pressure drop targets. When these inputs are treated as outputs rather than inputs, the first simulation can miss its temperature uniformity target and need redesign, so both are worth confirming early.<\/p><\/details> <details><summary><span class=\"q\">How reliable is CFD before cold plate tooling is committed?<\/span><span class=\"i\" aria-hidden=\"true\">+<\/span><\/summary><p>CFD results are only as firm as their boundary conditions, and heat load, inlet conditions and flow rate all need confirmed values. Teams working from estimated or placeholder figures should expect updated outputs once final cell parameters are locked. Tooling waits for your sign-off on the simulation in either case.<\/p><\/details> <details><summary><span class=\"q\">Can a thermal adhesive bond cells directly to the cold plate?<\/span><span class=\"i\" aria-hidden=\"true\">+<\/span><\/summary><p>Yes. Polyurethane structural adhesive 30107 is intended for bonding cells to the cold plate. The 0120 grade reaches 11 MPa Al\/Al shear strength with 2.05 W\/m\u00b7K conductivity measured to ASTM D5470. Surface-dry time is 35 minutes at 25 \u00b0C and the published full cure is 7 days at 23 \u00b1 2 \u00b0C; handling and fixture-release times are not published.<\/p><\/details> <details><summary><span class=\"q\">Which thermal pad suits cylindrical cells on a snake tube?<\/span><span class=\"i\" aria-hidden=\"true\">+<\/span><\/summary><p>Two reinforced 30101 constructions are listed for cylindrical cells and snake tube cold plates. PI film keeps the other properties of PI-tape reinforcement and suits pieces up to 500 \u00d7 420 mm. Glass-fiber cloth adds flexibility and body strength, conducts less heat than a plain pad and suits pieces up to 300 \u00d7 200 mm.<\/p><\/details> <details><summary><span class=\"q\">Are MOQ, pricing, payment and warranty terms published?<\/span><span class=\"i\" aria-hidden=\"true\">+<\/span><\/summary><p>Prototype cold plates are accepted in flexible quantities, while production MOQ depends on process: stamped parts with dedicated tooling carry a higher threshold than CNC or FSW parts. TIM MOQ, prices, payment terms, warranty and after-sales terms are not published on this page. Ask for them with your RFQ.<\/p><\/details> <details><summary><span class=\"q\">Will you sign an NDA before we send pack drawings?<\/span><span class=\"i\" aria-hidden=\"true\">+<\/span><\/summary><p>NDA and drawing-confidentiality terms are not published on this page and can be raised in the first message, before any drawings are sent, by email at oversea@trumonytechs.com or through the quote form. The quote inputs accept either a CAD drawing or boundary dimensions.<\/p><\/details> <details><summary><span class=\"q\">How long is shipping, and who handles import duties?<\/span><span class=\"i\" aria-hidden=\"true\">+<\/span><\/summary><p>Transit time depends on the destination port and shipping mode, and it is confirmed in the quote rather than published here. Import duties, customs clearance and local approvals depend on the destination country, so who carries each item should be settled before the order is placed.<\/p><\/details> <\/div> <\/section> <\/div> <\/main>","protected":false},"excerpt":{"rendered":"<p>EV &amp; ESS battery packs Cold plates, manifolds, TIM Custom Battery Pack Thermal Management Components for EV &amp; ESS Battery pack thermal management from Trumonytechs covers the heat path from cell to coolant: liquid cold plates, cooling tubes, manifolds and thermal interface materials, with CFD review before tooling. The cold plate configuration depends on cell &#8230; <a title=\"Termisk hantering av batteripaket\" class=\"read-more\" href=\"https:\/\/www.trumonytechs.com\/sv\/battery-pack-thermal-management\/\" aria-label=\"L\u00e4s mer om Battery Pack Thermal Management\">L\u00e4s mer<\/a><\/p>","protected":false},"author":2,"featured_media":26314,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-25436","page","type-page","status-publish","has-post-thumbnail"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.6 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Battery Pack Thermal Management - Trumonytechs<\/title>\n<meta name=\"description\" content=\"trumonytechs offers a complete Ev\/Ess Battery Pack Thermal Management that increases capacity while maintaining heat dissipation capability and greatly increases structural strength.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.trumonytechs.com\/sv\/termisk-hantering-av-batteripaket\/\" \/>\n<meta property=\"og:locale\" content=\"sv_SE\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Battery Pack Thermal Management - Trumonytechs\" \/>\n<meta property=\"og:description\" content=\"trumonytechs offers a complete Ev\/Ess Battery Pack Thermal Management that increases capacity while maintaining heat dissipation capability and greatly increases structural strength.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.trumonytechs.com\/sv\/termisk-hantering-av-batteripaket\/\" \/>\n<meta property=\"og:site_name\" content=\"Trumonytechs\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/trumonytechs\/\" \/>\n<meta property=\"article:modified_time\" content=\"2026-09-27T00:21:45+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/trumonytechs.com\/wp-content\/uploads\/2022\/08\/datwyler.com_battery_thermal-management.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"966\" \/>\n\t<meta property=\"og:image:height\" content=\"804\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:site\" content=\"@Trumonytechs\" \/>\n<meta name=\"twitter:label1\" content=\"Ber\u00e4knad l\u00e4stid\" \/>\n\t<meta name=\"twitter:data1\" content=\"5 minuter\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.trumonytechs.com\\\/battery-pack-thermal-management\\\/\",\"url\":\"https:\\\/\\\/www.trumonytechs.com\\\/battery-pack-thermal-management\\\/\",\"name\":\"Battery Pack Thermal Management - Trumonytechs\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.trumonytechs.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.trumonytechs.com\\\/battery-pack-thermal-management\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.trumonytechs.com\\\/battery-pack-thermal-management\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.trumonytechs.com\\\/wp-content\\\/uploads\\\/2022\\\/08\\\/datwyler.com_battery_thermal-management.jpg\",\"datePublished\":\"2025-01-17T00:14:01+00:00\",\"dateModified\":\"2026-09-27T00:21:45+00:00\",\"description\":\"trumonytechs offers a complete Ev\\\/Ess Battery Pack Thermal Management that increases capacity while maintaining heat dissipation capability and greatly increases structural strength.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.trumonytechs.com\\\/battery-pack-thermal-management\\\/#breadcrumb\"},\"inLanguage\":\"sv-SE\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.trumonytechs.com\\\/battery-pack-thermal-management\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"sv-SE\",\"@id\":\"https:\\\/\\\/www.trumonytechs.com\\\/battery-pack-thermal-management\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.trumonytechs.com\\\/wp-content\\\/uploads\\\/2022\\\/08\\\/datwyler.com_battery_thermal-management.jpg\",\"contentUrl\":\"https:\\\/\\\/www.trumonytechs.com\\\/wp-content\\\/uploads\\\/2022\\\/08\\\/datwyler.com_battery_thermal-management.jpg\",\"width\":966,\"height\":804,\"caption\":\"Battery Liquid Cooling System Overview-EV BATTERY PACK THERMAL MANAGEMENT\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.trumonytechs.com\\\/battery-pack-thermal-management\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.trumonytechs.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Battery Pack Thermal Management\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.trumonytechs.com\\\/#website\",\"url\":\"https:\\\/\\\/www.trumonytechs.com\\\/\",\"name\":\"Trumonytechs\",\"description\":\"Thermal Management System Solutions\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.trumonytechs.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.trumonytechs.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"sv-SE\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.trumonytechs.com\\\/#organization\",\"name\":\"Trumonytechs\",\"url\":\"https:\\\/\\\/www.trumonytechs.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"sv-SE\",\"@id\":\"https:\\\/\\\/www.trumonytechs.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.trumonytechs.com\\\/wp-content\\\/uploads\\\/2022\\\/06\\\/10001-1.png\",\"contentUrl\":\"https:\\\/\\\/www.trumonytechs.com\\\/wp-content\\\/uploads\\\/2022\\\/06\\\/10001-1.png\",\"width\":492,\"height\":250,\"caption\":\"Trumonytechs\"},\"image\":{\"@id\":\"https:\\\/\\\/www.trumonytechs.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/trumonytechs\\\/\",\"https:\\\/\\\/x.com\\\/Trumonytechs\",\"https:\\\/\\\/www.youtube.com\\\/channel\\\/UC2SyZohc9uTwFxzdTMLLlhw\",\"https:\\\/\\\/www.linkedin.com\\\/company\\\/81891179\\\/\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Termisk hantering av batteripaket - Trumonytechs","description":"trumonytechs erbjuder en komplett v\u00e4rmehantering f\u00f6r Ev\/Ess-batteripaket som \u00f6kar kapaciteten samtidigt som v\u00e4rmeavledningsf\u00f6rm\u00e5gan bibeh\u00e5lls och den strukturella styrkan \u00f6kar avsev\u00e4rt.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.trumonytechs.com\/sv\/termisk-hantering-av-batteripaket\/","og_locale":"sv_SE","og_type":"article","og_title":"Battery Pack Thermal Management - Trumonytechs","og_description":"trumonytechs offers a complete Ev\/Ess Battery Pack Thermal Management that increases capacity while maintaining heat dissipation capability and greatly increases structural strength.","og_url":"https:\/\/www.trumonytechs.com\/sv\/termisk-hantering-av-batteripaket\/","og_site_name":"Trumonytechs","article_publisher":"https:\/\/www.facebook.com\/trumonytechs\/","article_modified_time":"2026-09-27T00:21:45+00:00","og_image":[{"width":966,"height":804,"url":"https:\/\/trumonytechs.com\/wp-content\/uploads\/2022\/08\/datwyler.com_battery_thermal-management.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_site":"@Trumonytechs","twitter_misc":{"Ber\u00e4knad l\u00e4stid":"5 minuter"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.trumonytechs.com\/battery-pack-thermal-management\/","url":"https:\/\/www.trumonytechs.com\/battery-pack-thermal-management\/","name":"Termisk hantering av batteripaket - Trumonytechs","isPartOf":{"@id":"https:\/\/www.trumonytechs.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.trumonytechs.com\/battery-pack-thermal-management\/#primaryimage"},"image":{"@id":"https:\/\/www.trumonytechs.com\/battery-pack-thermal-management\/#primaryimage"},"thumbnailUrl":"https:\/\/www.trumonytechs.com\/wp-content\/uploads\/2022\/08\/datwyler.com_battery_thermal-management.jpg","datePublished":"2025-01-17T00:14:01+00:00","dateModified":"2026-09-27T00:21:45+00:00","description":"trumonytechs erbjuder en komplett v\u00e4rmehantering f\u00f6r Ev\/Ess-batteripaket som \u00f6kar kapaciteten samtidigt som v\u00e4rmeavledningsf\u00f6rm\u00e5gan bibeh\u00e5lls och den strukturella styrkan \u00f6kar avsev\u00e4rt.","breadcrumb":{"@id":"https:\/\/www.trumonytechs.com\/battery-pack-thermal-management\/#breadcrumb"},"inLanguage":"sv-SE","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.trumonytechs.com\/battery-pack-thermal-management\/"]}]},{"@type":"ImageObject","inLanguage":"sv-SE","@id":"https:\/\/www.trumonytechs.com\/battery-pack-thermal-management\/#primaryimage","url":"https:\/\/www.trumonytechs.com\/wp-content\/uploads\/2022\/08\/datwyler.com_battery_thermal-management.jpg","contentUrl":"https:\/\/www.trumonytechs.com\/wp-content\/uploads\/2022\/08\/datwyler.com_battery_thermal-management.jpg","width":966,"height":804,"caption":"Battery Liquid Cooling System Overview-EV BATTERY PACK THERMAL MANAGEMENT"},{"@type":"BreadcrumbList","@id":"https:\/\/www.trumonytechs.com\/battery-pack-thermal-management\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.trumonytechs.com\/"},{"@type":"ListItem","position":2,"name":"Battery Pack Thermal Management"}]},{"@type":"WebSite","@id":"https:\/\/www.trumonytechs.com\/#website","url":"https:\/\/www.trumonytechs.com\/","name":"Trumonytechs","description":"Systeml\u00f6sningar f\u00f6r v\u00e4rmehantering","publisher":{"@id":"https:\/\/www.trumonytechs.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.trumonytechs.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"sv-SE"},{"@type":"Organization","@id":"https:\/\/www.trumonytechs.com\/#organization","name":"Trumonytechs","url":"https:\/\/www.trumonytechs.com\/","logo":{"@type":"ImageObject","inLanguage":"sv-SE","@id":"https:\/\/www.trumonytechs.com\/#\/schema\/logo\/image\/","url":"https:\/\/www.trumonytechs.com\/wp-content\/uploads\/2022\/06\/10001-1.png","contentUrl":"https:\/\/www.trumonytechs.com\/wp-content\/uploads\/2022\/06\/10001-1.png","width":492,"height":250,"caption":"Trumonytechs"},"image":{"@id":"https:\/\/www.trumonytechs.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/trumonytechs\/","https:\/\/x.com\/Trumonytechs","https:\/\/www.youtube.com\/channel\/UC2SyZohc9uTwFxzdTMLLlhw","https:\/\/www.linkedin.com\/company\/81891179\/"]}]}},"_links":{"self":[{"href":"https:\/\/www.trumonytechs.com\/sv\/wp-json\/wp\/v2\/pages\/25436","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.trumonytechs.com\/sv\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.trumonytechs.com\/sv\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.trumonytechs.com\/sv\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.trumonytechs.com\/sv\/wp-json\/wp\/v2\/comments?post=25436"}],"version-history":[{"count":0,"href":"https:\/\/www.trumonytechs.com\/sv\/wp-json\/wp\/v2\/pages\/25436\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.trumonytechs.com\/sv\/wp-json\/wp\/v2\/media\/26314"}],"wp:attachment":[{"href":"https:\/\/www.trumonytechs.com\/sv\/wp-json\/wp\/v2\/media?parent=25436"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}